External hinged doors designed for offshore constructions as protection against hydrocarbon fires and explosions. Approved for jet fire.
Door leaf:
Reinforcement plates for hinges and door closer is provided and welded on the inside of the door leaf.
Door frame:
The profile of the frame is shaped to give maximum tightness, with 3 separate areas of impact. The frame is delivered for bolting or welding.
Hinges:
The hinges are bolted to the door leaf and welded to the door frame.
The hinges are provided with washers between the top and bottom parts to reduce friction.
Options available:
- Single and double doors
- Panic bar
- Semi-watertight
- Vision panel
- Blast
- Pneumatic operated hinge door
- Gas-tight
- Fire Class
- null
- Sound Reduction
- Rw 54 dBdB
- Manufacturer
Description | Fire Class | Operation | Surface doorleaf | Frame (and top element) | Thickness doorleaf (mm) | Weight (c.o. 750 mm/kg) | Clear opening size (mm) | Sound Reduction (dB) | Application | Comments |
---|---|---|---|---|---|---|---|---|---|---|
H-120H single hinged | H-120 | Manual | 2 mm (alt 3) painted mild or stainless steel | 3 mm (alt 4 or 5 mm) painted mild or stainless steel | 129 | 220 | 1000 x 2142 | Rw = 54 | Offshore platforms | NA |
H-120HH double hinged | H-120 | Manual | 2 mm (alt 3) painted mild or stainless steel | 3 mm (alt 4 or 5 mm) painted mild or stainless steel | 129 | 410 | 2000 x 2080 | Rw = 54 | Offshore platforms | NA |